Irritrol Total Control R Series Controller
Maximum scheduling flexibility in an easy-to-use format makes this innovative controller ideal for a wide range of sophisticated watering requirements.
KEY FEATURES & BENEFITS
· New “R” models are remote ready – compatible with Toro TMR-1-KIT maintenance remote.
· Four independent programs offer concurrent operation capability-for scheduling flexibility.
· Seven-day calendar, odd/even day or day-interval options of one to 30 days – provides the flexibility to meet water restrictions or plant water requirements.
· Programmable master valve on/off per program. Provides the flexibility of running some programs with a booster pump and some without.
· Non-volatile memory. Holds program during power failures for reliable operation.
· Snap-out design. Allows for easy removal of control module without disturbing valve wiring for hassle-free station upgrade and servicing.
· Flexible station run times and start times. Meets a broad range of watering requirements.
· Sensor hooked up with bypass switch compatible with the wireless Rainsensor™ series. Saves water by shutting off the system during rain.
ADDED FEATURES
· User-friendly, 10-position programming dial and large, easy-to-read display.
· Excluded-day option, when used with the odd/even day option, allows selection of specific day(s) not to water.
· 365-day calendar for odd/even day programming.
· Start time stacking within each program.
· Water budgeting.
· Programmable “Rain Off” up to seven days.
· Automatic, semi-automatic, manual and timed-manual operation.
· Self-diagnostic circuit breaker identifies and overrides an electrical malfunction on a valve.
· Electrical surge protection (on both input and output lines) resists damage from lightning storms and power outages.
· Battery backup keeps accurate time for up to 90 days during power failures.
· Valve test terminal for easy valve identification.
· Weather-resistant, plastic key-lock cabinet with an internal transformer.
· Wall mounted.
· Complies with Australian electrical safety standards; C Tick approved.
OPERATING SPECIFICATIONS
· Station run times: 1 minute to 10 hours in 1-minute increments.
· Start times: 16 Total starts assignable to any program.
· Watering schedule: 7-day calendar, odd/even day or interval option of 1-30 days.
· Watering budgeting: 10-200% in 10% increments.
ELECTRICAL SPECIFICATIONS
· Electrical circuit breaker: 1.25 amps minimum holding.
· Maximum output per station: 24 VAC, 0.5 amps.
· Maximum output to valves: 24 VAC, 1.25 amps (including master valve).
· Battery backup: 9-volt alkaline battery (not included).
· Transformer input: 240 VAC, 50 Hz.
· Transformer output: 24 VAC, 1.67 amps.