INSTALLATION INSTRUCTIONS
IMPORTANT: Turn off power before installing or removing the connector.
1. Strip wires ½”.
2. Align frayed strands or conductors.
3. No Pre-twisting needed. Hold wires together with ends even. Note: Twist and lead stranded wires slightly.
4. Push wires firmly into connector when starting.
5. Twist connector onto wires pushing firmly until tight. Do not over torque. Do not reuse.
PRODUCT SPECIFICATIONS & MEASUREMENTS
Max. Voltage: 30V/10 AMP
Connector Size: 13/16” x 1 9/16”
Wire Type: Copper/Copper
Wire Range: Min #22 / Max #6
Temperature Rating: 75°C (167°F)
Petroleum Sealant: -29° to 250°F